Description

In response to the official classification of formaldehyde as a category 1B carcinogen, a company in Slovenia that used the substance in manufacturing insulation products set out to assess the current situation and introduce preventive measures to improve workers’ safety and health. This good practice example details how the company, primarily by substituting resins with formaldehyde content low enough that they were not classified as carcinogenic, was able to significantly reduce exposure levels. The substitution had other good effects, resulting in a higher quality product and lower environmental impact.

Other data

Provider
Provider name (English)
Ursa
Provider name (Original)
Ursa Slovenija d.o.o.
Provider url:
Type of provider
Tasks covered
Applying Glues or Sealants
Hazard - physical state
Aerosols
Gases
Vapours
Hazard - health effects
Skin sensitisers
Carcinogens
Mutagens
Irritants
Exposure route
Dermal contact
Inhalation
Substance Description

Formaldehyde

CAS Number
50 -00- 0
EC number
200 -001- 8
Prevention measures
Level 1. Substitution
Purpose of the material
Other
Target group
Employers
Safety officers
Workers